Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 251
Filtrar
1.
Front Cardiovasc Med ; 11: 1333265, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38660479

RESUMEN

Introduction: Neural crest cells (NCCs) are multipotent and are attributed to the combination of complex multimodal gene regulatory mechanisms. Cardiac neural crest (CNC) cells, originating from the dorsal neural tube, are pivotal architects of the cardio-neuro-vascular domain, which orchestrates the embryogenesis of critical cardiac and vascular structures. Remarkably, while the scientific community compiled a comprehensive inventory of neural crest derivatives by the early 1980s, our understanding of the CNC's role in various cardiovascular disease processes still needs to be explored. This review delves into the differentiation of NCC, specifically the CNC cells, and explores the diverse facets of non-syndromic cardiovascular neurocristopathies. Methods: A systematic review was conducted as per the PRISMA Statement. Three prominent databases, PubMed, Scopus, and Embase, were searched, which yielded 1,840 studies. We excluded 1,796 studies, and the final selection of 44 studies formed the basis of this comprehensive review. Results: Neurocristopathies are a group of genetic disorders that affect the development of cells derived from the NC. Cardiovascular neurocristopathy, i.e., cardiopathy and vasculopathy, associated with the NCC could occur in the form of (1) cardiac septation disorders, mainly the aortico-pulmonary septum; (2) great vessels and vascular disorders; (3) myocardial dysfunction; and (4) a combination of all three phenotypes. This could result from abnormalities in NCC migration, differentiation, or proliferation leading to structural abnormalities and are attributed to genetic, familial, sporadic or acquired causes. Discussion: Phenotypic characteristics of cardiovascular neurocristopathies, such as bicuspid aortic valve and thoracic aortic aneurysm, share a common embryonic origin and are surprisingly prevalent in the general population, necessitating further research to identify the underlying pathogenic and genetic factors responsible for these cardiac anomalies. Such discoveries are essential for enhancing diagnostic screening and refining therapeutic interventions, ultimately improving the lives of individuals affected by these conditions.

2.
Front Surg ; 11: 1361963, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38638141

RESUMEN

Background: This study evaluates the implications of blood pressure homeostasis in bilateral vs. unilateral carotid surgeries, focusing on the incidence of postoperative hypertension, hyperperfusion syndrome, and stroke as primary outcomes. It further delves into the secondary outcomes encompassing major adverse cardiovascular events and all-cause mortality. Methods: Spanning two decades (2002-2023), this comprehensive retrospective research encompasses 15,369 carotid referrals, out of which 1,230 underwent carotid interventions. A subset of 690 patients received open carotid procedures, with a 10-year follow-up, comprising 599 unilateral and 91 bilateral surgeries. The Society for Vascular Surgery Carotid Reporting Standards underpin our methodological approach for data collection. Both univariate and multivariate analyses were utilized to identify factors associated with postoperative hypertension using the Statistical Package for the Social Sciences (SPSS) Version 22 (SPSS®, IBM® Corp., Armonk, N.Y., USA). Results: A marked acute elevation in blood pressure was observed in patients undergoing both unilateral and bilateral carotid surgeries (p < 0.001). Smoking (OR: 1.183, p = 0.007), hyperfibrinogenemia (OR: 0.834, p = 0.004), emergency admission (OR: 1.192, p = 0.005), severe ipsilateral carotid stenosis (OR: 1.501, p = 0.022), and prior ipsilateral interventions (OR: 1.722, p = 0.003) emerged as significant factors that correlates with postoperative hypertension in unilateral surgeries. Conversely, in bilateral procedures, gender, emergency admissions (p = 0.012), and plaque morphology (p = 0.035) significantly influenced postoperative hypertension. Notably, 2.2% of bilateral surgery patients developed hyperperfusion syndrome, culminating in hemorrhagic stroke within 30 days. Intriguingly, postoperative stage II hypertension was identified as an independent predictor of neurological deficits post-secondary procedure in bilateral CEA cases (p = 0.004), attributable to hyperperfusion syndrome. However, it did not independently predict myocardial infarction or mortality outcomes. The overall 30-day stroke rate stood at 0.90%. Lowest incidence of post operative hypertension or any complications were observed in eversion carotid endartrertomy. Conclusion: The study identifies postoperative hypertension as a crucial independent predictor of perioperative stroke following bilateral carotid surgery. Moreover, the study elucidates the significant impact of bilateral CEA on the development of post-operative hyperperfusion syndrome or stroke, as compared to unilateral CEA. Currently almost 90% of our carotid practice is eversion carotid endartrerectomy.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38423848

RESUMEN

PURPOSE: To evaluate the safety and effectiveness of the novel, next-generation Myval Octacor - Transcatheter Heart Valve (THV) in patients with severe, symptomatic, native aortic stenosis (AS). METHODS: This multicenter, real-world observational registry included 123 patients with severe symptomatic AS, across 16 Indian centers who underwent treatment with the novel Myval Octacor THV. Study endpoints included all-cause mortality, all stroke, acute kidney injury (AKI), major vascular complications, moderate or severe paravalvular leakage (PVL) and new permanent pacemaker implantation (PPI) until 30 days follow-up. RESULTS: Of the 123 patients (average age 70.07 ± 8.33 years), 37.4 % (n = 46) were female and 39.84 % presented with bicuspid valves. The technical success rate of the procedure was 100 % and the device success rate at 30 days was 98.4 %. At 30 days (n = 123) after the procedure, the overall mortality was 1.6 %. AKI occurred in 1.6 % of patients and there was no incidence of stroke, bleeding (types 3 and 4), and major vascular complications. In an analysis of 31 patients whose echocardiographic parameters were available across all timepoints, there were significant improvements in the mean pressure gradient (54.31 ± 18.19 mmHg vs. 10.42 ± 4.24 mmHg; p < 0.0001) and effective orifice area (0.66 ± 0.21 cm2 vs. 1.80 ± 0.44 cm2; p < 0.0001) from baseline to the 30-day follow-up. None of the patients experienced severe PVL, while moderate PVL was observed in two patients (1.6 %). CONCLUSIONS: Early outcomes of the next-generation, novel Myval Octacor THV proved its safety and effectiveness in the treatment of severe AS.

5.
Expert Rev Med Devices ; 21(1-2): 109-120, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38166517

RESUMEN

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is becoming the standard of care for severe symptomatic aortic stenosis (AS). Yet, some patients with AS are not indicated/eligible for TAVI. Several noninvasive, catheter-based or surgical alternatives exist, and other therapeutic options are emerging. AREAS COVERED: This review provides an overview of non-TAVI options for severe AS. Non-invasive, transcatheter, and alternative surgical strategies are discussed, emphasizing their backgrounds, techniques, and outcomes. EXPERT OPINION: Alternative therapies to TAVI, whether device-based or non-device-based, continue to evolve or emerge and provide either alternative treatments or a bridge to TAVI, for patients not meeting indications for, or having contraindications to TAVI.Although TAVI and SAVR are the current dominant therapies, there are still some patients that could benefit in the future from other alternatives.Data on alternative options for such patients are scarce. Many advantages and disadvantages arise when selecting a specific treatment strategy for individual patients.Head-to-head comparison studies could guide physicians toward better patient selection and procedural planning. Awareness of therapeutic options, indications, techniques, and outcomes should enable heart teams to achieve optimized patient selection. Furthermore, it can increase the use of these alternatives to optimize the management of AS among different patient populations.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Riesgo
6.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38244892

RESUMEN

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/métodos , Calcio , Resultado del Tratamiento , Estudios Retrospectivos , Diseño de Prótesis
7.
Comput Biol Med ; 168: 107714, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38035862

RESUMEN

BACKGROUND: Balloon burst during transcatheter aortic valve replacement (TAVR) is serious complication. This study pioneers a novel approach by combining image observation and computer simulation validation to unravel the mechanism of balloon burst in a patient with bicuspid aortic valve (BAV) stenosis. METHOD: A new computational model for balloon pre-dilatation was developed by incorporating the element failure criteria according to the Law of Laplace. The effects of calcification and aortic tissue material parameters, friction coefficients, balloon types and aortic anatomy classification were performed to validate and compare the expansion behavior and rupture mode of actual balloon. RESULTS: Balloon burst was dissected into three distinct stages based on observable morphological changes. The mechanism leading to the complete transverse burst of the non-compliant balloon initiated at the folding edges, where contacted with heavily calcified masses at the right coronary sinus, resulting in high maximum principal stress. Local sharp spiked calcifications facilitated rapid crack propagation. The elastic moduli of calcification significantly influenced balloon expansion behavior and crack morphology. The simulation case of the calcific elastic modulus was set at 12.6 MPa could closely mirror clinical appearance of expansion behavior and crack pattern. Furthermore, the case of semi-compliant balloons introduced an alternative rupture mechanism as pinhole rupture, driven by local sharp spiked calcifications. CONCLUSIONS: The computational model of virtual balloons could effectively simulate balloon dilation behavior and burst mode during TAVR pre-dilation. Further research with a larger cohort is needed to investigate the balloon morphology during pre-dilation by using this method to guide prosthesis sizing for potential favorable outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Dilatación , Simulación por Computador , Análisis de Elementos Finitos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Resultado del Tratamiento , Diseño de Prótesis
8.
Clin Res Cardiol ; 113(1): 116-125, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37553516

RESUMEN

BACKGROUND: Estimation of regurgitant fraction by videodensitometry (VD-AR) of aortic root angiograms is a new tool for objective grading of paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI). Stratification with boundaries at 6% and 17% has been proposed to reflect "none/trace", "mild" and "moderate or higher" PVR. OBJECTIVE: We sought to investigate the association of strata of VD-AR with 3-year mortality and to compare VD-AR with visual grading of angiograms. METHODS: We interrogated our database for patients undergoing transfemoral TAVI from 2008 to 2018. Vital status of the patients was obtained from population registers. To test differences in survival and estimate adjusted hazard ratios (HRs) we fitted Cox models. RESULTS: Our retrospective study included 699 patients with evaluable angiograms at completion of the TAVI procedure. Cumulative 3-year mortality was 35.0% in 261 (37.3%) patients with VD-AR < 6%, 33.9% in 325 (46.5%) patients with VD-AR between 6 and 17% (HR [95% confidence interval] 1.06 [0.80-1.42]; P = 0.684) and 47.2% in 113 (16.2%) patients with VD-AR > 17% (HR 1.57 [1.11-2.22]; P = 0.011). Visually, PVR was graded as "none/trace" in 470 (67.2%) patients, as "mild" in 219 (31.3%) and as "moderate" in 10 (1.4%). Both mild PVR and moderate PVR on visual grading were significantly associated with mortality (HRs 1.31 [1.12-1.54]; P = 0.001 and 1.92 [1.13-3.24]; P = 0.015; respectively). CONCLUSIONS: VD-AR > 17%, but not VD-AR 6-17%, was independently associated with mortality. Compared with subjective visual evaluation, VD-AR resulted in a smaller proportion of patients with PVR classified as prognostically relevant.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Angiografía , Modelos de Riesgos Proporcionales , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
9.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
10.
Heart Fail Rev ; 29(2): 479-496, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38112937

RESUMEN

Hypertrophic cardiomyopathy (HCM) is the most common heritable myocardial disorder worldwide. Current pharmacological treatment options are limited. Mavacamten, a first-in-class cardiac myosin inhibitor, targets the main underlying pathology of HCM. We conducted a systematic review and meta-analysis to evaluate the efficacy and safety of Mavacamten in patients with HCM. PRISMA flow chart was utilized using PubMed, SCOPUS, and Cochrane databases for all up-to-date studies using pre-defined keywords. Pre-specified efficacy outcomes comprised several parameters, including an improvement in peak oxygen consumption (pVO2) and ≥ 1 NYHA class, the need for septal reduction therapy (SRT), change from baseline in Kansas City Cardiomyopathy Questionnaire (KCCQ), changes in biochemical markers and LVEF, along with peak left ventricular outflow tract gradient at rest and after Valsalva maneuver. Safety outcomes included morbidity and serious adverse events. This systematic review included five studies, four RCTs and one non-randomized control trial comprised a total of 524 (Mavacamten [273, 54.3%] vs placebo [230, 45.7%] adult (≥ 18 years) patients with a mean age of 56 years. The study. comprised patients with Caucasian and Chinese ethnicity and patients with obstructive (oHCM) and non-obstructive (nHCM) HCM. Most baseline characteristics were similar between the treatment and placebo groups. Mavacamten showed a statistically significant increase in the frequency of the primary composite endpoint (RR = 1.92, 95% CI [1.28, 2.88]), ≥ 1 NYHA class improvement (RR = 2.10, 95% CI [1.66, 2.67]), a significant decrease in LVEF, peak left ventricular outflow tract gradient at rest and after Valsalva maneuver. Mavacamten also showed a significant reduction in SRT rates (RR = 0.29, 95% CI [0.21, 0.40], p < 0.00001), KCCQ clinical summary scores (MD = 8.08, 95% CI [4.80, 11.37], P < 0.00001) troponin levels and N-terminal pro-B-type natriuretic peptide levels. However, there was no statistically significant difference between Mavacamten and placebo regarding the change from baseline peak oxygen consumption. Mavacamten use resulted in a small increase in adverse events but no statistically significant increment in serious adverse events. Our study showed that Mavacamten is a safe and effective treatment option for Caucasian and Chinese patients with HCM on the short-term. Further research is needed to explore the long-term safety and efficacy of Mavacamten with HCM. In addition, adequately powered studies including patients with nHCM is needed to ascertain befits of Mavacamten in those patients.


Asunto(s)
Cardiomiopatía Hipertrófica , Uracilo/análogos & derivados , Adulto , Humanos , Persona de Mediana Edad , Cardiomiopatía Hipertrófica/tratamiento farmacológico , Corazón , Bencilaminas/efectos adversos , Miocardio
11.
Z Orthop Unfall ; 2023 Nov 22.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-37992733

RESUMEN

The treatment of patients with ISJ dysfunction is difficult due to the multifactorial causes of pain and various problems in clarification. Treatment includes physical therapy, corticosteroids, prolotherapy, radiofrequency denervation and sacroiliac joint fusion. A new option for the surgical treatment of ISG dysfunction is the Torpedo implant system. For a safe fusion, only 2 implants are needed, which are available in lengths of 30-50 mm. The new implant system has been tested in pilot studies for efficacy and biocompatibility with good results. For further documentation for the Torpedo implant system, a comparative study against the iFuse system was carried out.Two different implants were used: Group 1: Deltacor Torpedo, Group 2: iFuse implants (Si-Bone). The data generated during admission and subsequent check-ups (VAS, ODI, opioid use) were entered into an evaluation file set up for this purpose. Follow-up appointments were set at 1 month, 3, 6 and 12 months postoperatively.The data of 65 patients were evaluated comparatively. In all comparisons, only very small effect sizes were found with regard to the differences in the decrease in pain intensities, so that equivalent effectiveness of the two methods could initially be postulated from a clinical point of view. Most patients in both groups reported taking opioids to treat pain before surgery. According to the decrease in pain intensity, opioid treatment could be discontinued in some patients after the operation. After 12 months, the number of patients treated with opioids decreases to 23% in group 1 and to 17% in group 2. The success of the fusions with the two methods can also be proven by image documentation, from which the position of the implants can also be clearly recognised. In no case was there any loosening.Overall, the evaluation of this study allows the conclusion that both implant systems can be successfully used for the treatment of patients with ISJ syndrome. The present results should be confirmed in further comparative studies with the proposed evaluation methods.

12.
Expert Rev Med Devices ; 20(12): 1065-1077, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37933200

RESUMEN

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is the standard of care for selected patients with severe aortic stenosis, irrespective of the surgical risk. Over the last two decades of TAVI practice, multiple limitations were identified. In addition, the extension of TAVI into a wider patient spectrum created new challenges. AREAS COVERED: This review provides an overview of emerging transcatheter heart valves (THVs) beyond the approved contemporary THVs for the treatment of aortic stenosis. EXPERT OPINION: The incidence of degenerative aortic stenosis is expected to increase with more aging of the population. Therefore, TAVI needs to meet this increase in the number of patients indicated for aortic valve replacement alongside a wide and complex anatomical variability. An increasing number of Aortic THVs are available in the market. This includes upgraded iterations of contemporary devices and innovative devices developed by emerging manufacturers. The new devices aim for the reduction or elimination of undesirable outcomes like paravalvular leakage and conduction disturbances requiring permanent pacemaker implantation. Alternatively, emerging THVs should provide feasibility regarding yet unproven TAVI indications like Bicuspid aortic valve, aortic regurgitation, or very large anatomy. Furthermore, some of the emerging THVs are designed to tackle the long-term durability issue of biological valves.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos
13.
Int J Nanomedicine ; 18: 5749-5780, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37849641

RESUMEN

Background: Despite recent advances in wound healing products, phytochemicals have been considered promising and attractive alternatives. Carvacrol (CAR), a natural phenolic compound, has been reported to be effective in wound healing. Purpose: This work endeavored to develop novel CAR-loaded phytosomes for the enhancement of the wound healing process. Methods: Molecular docking was performed to compare the affinities of the different types of phospholipids to CAR. Phytosomes were prepared by three methods (thin-film hydration, cosolvency, and salting out) using Lipoid S100 and Phospholipon 90H with three levels of saturation percent (0%, 50%, and 100%), and three levels of phospholipid molar percent (66.67%, 75%, and 80%). The optimization was performed using Design Expert where particle size, polydispersity index, and zeta potential were chosen as dependent variables. The optimized formula (F1) was further investigated regarding entrapment efficiency, TEM, 1H-NMR, FT-IR, DSC, X-RD, in vitro release, ex vivo permeation, and stability. Furthermore, it was incorporated into a hydrogel formulation, and an in vivo study was conducted to investigate the wound-healing properties of F1. Results: F1 was chosen as the optimized formula prepared via the thin-film hydration method with a saturation percent and a phospholipid molar percent of zero and 66.67, respectively. TEM revealed the spherical shape of phytosomal vesicles with uniform size, while the results of 1H-NMR, FT-IR, DSC, and X-RD confirmed the formation of the phytosomal complex. F1 demonstrated a higher in vitro release and a slower permeation than free CAR. The wound area of F1-treated animals showed a marked reduction associated with a high degree of collagen fiber deposition and enhanced cellular proliferation. Conclusion: F1 can be considered as a promising remedy for the enhancement of wound healing and hence it would be hoped to undergo further investigation.


Asunto(s)
Fitosomas , Cicatrización de Heridas , Animales , Simulación del Acoplamiento Molecular , Espectroscopía Infrarroja por Transformada de Fourier , Fosfolípidos , Tamaño de la Partícula
14.
J Clin Med ; 12(19)2023 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-37834939

RESUMEN

BACKGROUND: This review focuses on multimodality imaging of cardiotoxicity in cancer patients, with the aim of evaluating the effectiveness of different techniques in detecting and monitoring cardiac changes associated with cancer therapy. METHODS: Eight studies were included in the review, covering various imaging modalities such as cardiac magnetic resonance imaging, echocardiography, and multigated acquisition scanning. RESULTS: Cardiac magnetic resonance imaging emerged as the most definitive modality, offering real-time detection, comprehensive assessment of cardiac function, the ability to detect early myocardial changes, and superior detection of cardiotoxicity when compared to the other imaging modalities. The studies also emphasize the importance of parameters such as left ventricular ejection fraction and global longitudinal strain in assessing cardiac function and predicting cardiotoxicity. CONCLUSION: Due to the common use of HER2 agents and anthracyclines within the breast cancer population, the LVEF as a critical prognostic measurement for assessing heart health and estimating the severity of left-sided cardiac malfunction is a commonly used endpoint. CTRCD rates differed between imaging modalities, with cardiac MRI the most sensitive. The use of multimodal cardiac imaging remains a nuanced area, influenced by local availability, the clinical question at hand, body habits, and medical comorbidities. All of the imaging modalities listed have a role to play in current care; however, focus should be given to increasing the provision of cardiac MRI for breast cancer patients in the future to optimize the detection of CTRCD and patient outcomes thereafter.

16.
Front Cardiovasc Med ; 10: 1161779, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37529710

RESUMEN

Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.

17.
Int J Pharm X ; 6: 100201, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37560488

RESUMEN

The objective of this study was to encapsulate the antibacterial drug levofloxacin hemihydrate (LF) into spanlastics (SLs) followed by incorporation into gelrite in situ gel to enhance its antibacterial activity and sustain ocular delivery. A combination of Span 60 as main vesicle component and Tweens as an edge activator (EA) was used to prepare SLs using the thin film hydration method. A 32 factorial design was applied to study the effect of formulation variables (ratio of Span 60: EA and type of EA) on SLs characteristics (encapsulation efficiency (EE%), particle size (PS), zeta potential (ZP) and percentage of drug released). In-vitro antimicrobial study was conducted to determine the antibacterial activity of the optimized formula. Finally confocal laser scanning microscopy (CLSM) was applied to monitor SLs corneal penetration. The optimum formulation (F5), contains 240 mg Span 60 and 60 mg Tween 60 as EA. F5 exhibited EE% = 59.7 ± 4.2%, PS = 177.6 ± 1.8 nm, PDI = 0.27 ± 0.022 and ZP = -40.6 ± 0.68 mV. Furthermore, only 39.37 ± 0.72% of LF amount was released after 4 h compared to complete release from drug solution. The apparent permeation coefficient was (14.7 × 10-3 cm/h) compared to (9.7 × 10-3 cm/h) for LF solution. Moreover, F5 exhibited 200% and 100% increase in the antibacterial efficacy against Pseudomonas aeruginosa and Staphylococcus aureus respectively.

18.
J Clin Med ; 12(14)2023 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-37510950

RESUMEN

(1) Background: Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to investigate the predictors of PPM at 30 days after TAVI using Evolut R/PRO/PRO+; (2) Methods: Consecutive patients who underwent TAVI with the Evolut platform between October 2019 and August 2022 at University Hospital Galway, Ireland, were included. Patients who had a prior PPM (n = 10), valve-in-valve procedures (n = 8) or received >1 valve during the index procedure (n = 3) were excluded. Baseline clinical, electrocardiographic (ECG), echocardiographic and multislice computed tomography (MSCT) parameters were analyzed. Pre-TAVI MSCT analysis included membranous septum (MS) length, a semi-quantitative calcification analysis of the aortic valve leaflets, left ventricular outflow tract, and mitral annulus. Furthermore, the implantation depth (ID) was measured from the final aortography. Multivariate binary logistic analysis and receiver operating characteristic (ROC) curve analysis were used to identify independent predictors and the optimal MS and ID cutoff values to predict new PPM requirements, respectively; (3) Results: A total of 129 TAVI patients were included (age = 81.3 ± 5.3 years; 36% female; median EuroSCORE II 3.2 [2.0, 5.4]). Fifteen patients (11.6%) required PPM after 30 days. The patients requiring new PPM at 30 days were more likely to have a lower European System for Cardiac Operative Risk Evaluation II, increased prevalence of right bundle branch block (RBBB) at baseline ECG, have a higher mitral annular calcification severity and have a shorter MS on preprocedural MSCT analysis, and have a ID, as shown on the final aortogram. From the multivariate analysis, pre-TAVI RBBB, MS length, and ID were shown to be predictors of new PPM. An MS length of <2.85 mm (AUC = 0.85, 95%CI: (0.77, 0.93)) and ID of >3.99 mm (area under the curve (AUC) = 0.79, (95% confidence interval (CI): (0.68, 0.90)) were found to be the optimal cut-offs for predicting new PPM requirements; (4) Conclusions: Membranous septum length and implantation depth were found to be independent predictors of new PPM post-TAVI with the Evolut platform. Patient-specific implantation depth could be used to mitigate the requirement for new PPM.

19.
J Am Heart Assoc ; 12(15): e029464, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37489732

RESUMEN

Background ACURATE neo2 is a transcatheter aortic valve implantation system consisting of a self-expanding bioprosthetic valve with supra-annular leaflet position and featuring innovations to facilitate placement accuracy and reduce paravalvular regurgitation. Methods and Results The goal of the Early neo2 (Early neo2 Registry of the ACURATE neo2 TAVI Prosthesis) was to gather real-life data on safety and efficacy in a European transcatheter aortic valve implantation population treated with ACURATE neo2. Data were collected from 554 consecutive patients treated with ACURATE neo2 at 12 European sites (mean age, 82 years; 66% women; mean European System for Cardiac Operative Risk Evaluation II, 4.5%±3.8%) between September 2020 and March 2021. The composite primary end point was the occurrence of any of the following: postoperative (in-hospital) paravalvular regurgitation grade ≥2, in-hospital acute kidney injury stage 3, postoperative pacemaker implantation, 30-day death, and 30-day stroke. The primary end point occurred in 12.6% of patients. The 30-day rates for all-cause death and all stroke were 1.3% and 2.7%, respectively, and 1.5% of patients exhibited stage 3 acute kidney injury. A total of 34 patients (6.2%) received a postoperative permanent pacemaker. Per core laboratory-adjudicated echocardiographic analysis, mean postoperative aortic valve gradient was 7.6±3.3 mm Hg, and 2.8% of patients exhibited paravalvular regurgitation grade ≥2. Conclusions In this report of postmarket use of the ACURATE neo2 valve in a real-world transcatheter aortic valve implantation population, patients exhibited favorable postoperative hemodynamics and clinical outcomes and a low rate of postoperative pacemaker implantation.


Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Sistema de Registros , Accidente Cerebrovascular/epidemiología
20.
JACC Heart Fail ; 11(8 Pt 1): 865-878, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37269258

RESUMEN

Late right heart failure (RHF) is increasingly recognized in patients with long-term left ventricular assist device (LVAD) support and is associated with decreased survival and increased incidence of adverse events such as gastrointestinal bleeding and stroke. Progression of right ventricular (RV) dysfunction to clinical syndrome of late RHF in patients supported with LVAD is dependent on the severity of pre-existing RV dysfunction, persistent or worsening left- or right-sided valvular heart disease, pulmonary hypertension, inadequate or excessive left ventricular unloading, and/or progression of the underlying cardiac disease. RHF likely represents a continuum of risk with early presentation and progression to late RHF. However, de novo RHF develops in a subset of patients leading to increased diuretic requirement, arrhythmias, renal and hepatic dysfunction, and heart failure hospitalizations. The distinction between isolated late RHF and RHF due to left-sided contributions is lacking in registry studies and should be the focus of future registry data collection. Potential management strategies include optimization of RV preload and afterload, neurohormonal blockade, LVAD speed optimization, and treatment of concomitant valvular disease. In this review, the authors discuss definition, pathophysiology, prevention, and management of late RHF.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Disfunción Ventricular Derecha , Humanos , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Sistema de Registros , Ventrículos Cardíacos , Disfunción Ventricular Derecha/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...